JM TPO Roofing Membrane

JM TPO Roofing Membrane

Product Descriptive Name
Thermoplastic Polyolefin Membrane
Product Short Description
JM TPO gives you a more cost-effective, yet highly reliable solution for your roofing projects. Our membranes are reinforced with a polyester fabric and manufactured with an ultraviolet-resistant thermoplastic polyolefin formulation. This combination provides you with extreme pliability, flexibility and weldability.

Product Details

JM TPO Roofing Membrane

Product Long Description

Features

JM TPO Roofing Membrane

Features

Meets or exceeds the requirements of ASTM D 6878

Thickness Over Scrim: Optimized and tested on a continual basis with a state-of-the-art thickness gauge to verify that the thickness valued by our customers in incorporated into the sheet.

One of the Widest Melt Windows: Promotes better welds over a wider variety of speeds and temperatures, and leads to a softer, more flexible and workable sheet.

Reinforced Fabric Scrim Layer and Top-Ply Thickness: Lends to durable physical properties including:

  • Long-term weathering, UV resistance and heat-aging properties
  • High breaking and tearing strength

Optimized TPO Formulation: Delivers high-performance ozone resistance, cool roof reflectivity and overall weather resistance.

Documents

TPO Installation and Details

When it comes to design, we've got the tools to get you from the desk to the roof. Here you will find all of the TPO specifications, 3-part specs, details and installation guides. If you have any questions when it comes to installation, please contact our Specifier Services Group for design and your local technical representative for the field.

TPO System Detail Decoder

TPO MASTER DETAILS
CADPDFBIM
T-FW-M1  TPO Base & Wall Flashing with Coping Master Detail
DWGPDF-
T-FW-M1I TPO Base & Wall Flashing with Coping Isometric View Master Detail
DWGPDF-
T-FW-M2I Highwall Flashing with Metal Backing Strip Isometric View Master Detail
DWGPDF-
T-FW-M3I TPO Self Adhered Base & Wall Flashing with Coping Isometric View
DWGPDF-
T-FW-M4I TPO Base and Wall Flashing with Coping ISO View
DWGPDF-
T-FW-M5I TPO RhinoBond Wall Flashing ISOmetric View
DWGPDF-
T-FW-M6I TPO Rhinobond Wall Flashing ISO Metric View
DWGPDF-
T-FW-M7I TPO Base and Wall Flashing 10 FT Max with Coping
DWGPDF-

BASE TIE-IN DETAILSCAD  PDF BIM
T-FW-B1 Base Flashing with Horizontal Reinforced Termination Strip - RTSDWGPDFRVT
T-FW-B2 Base Flashing with Vertical Reinforced Termination Strip - RTSDWGPDF-
T-FW-B3 Base Tie-In Fastener & PlateDWGPDFRVT
T-FW-B4 Base Tie-In Fastener & Plate on WallDWGPDF-
T-FW-B5 Membrane Flashing Base Tie-In - High Internal PressureDWGPDFRVT
T-FW-B6 Base Tie-In - RhinoPlate SystemDWGPDF-
T-FW-B7 Base Tie-in Knee Wall Brace 2/12 SlopeDWGPDF-
T-FW-B8 Base Tie-In (Loose Hung Flashing)DWGPDF-
T-FW-B9 TPO Self Adhered Base Tie-In (Fastener & Plate)DWGPDF-
T-FW-B10 TPO Self Adhered Base Tie-In (Fastener & Plate) On WallDWGPDF-
T-FW-B11 TPO Self Adhered Membrane Flashing Base Tie-In (High Internal Pressure)DWGPDF-
T-FW-B12 TPO Self Adhered Base Tie-In (Fastener & Plate) with TPO Cover StripDWGPDF-
T-FW-B13 Base Tie-In Fleece Backed TPO in RSUADWGPDF-
T-FW-B13I TPO Fleece backed in RSUA Base and Wall FlashingDWGPDF-
T-FW-B14 Base Tie-In Fleece Backed TPO in Two Part UIA SpatterDWGPDF-
T-FW-B14I TPO Fleece Backed Base and Wall in Two Part UIA SpatterDWGPDF-
T-FW-B15 TPO Base Flashing with Cant StripDWGPDF-
T-FW-B16 TPO Coated Metal Base Tie-In with BreakDWGPDF-
T-FW-B17 Spliced TPO Coated Metal Base Tie-In with BreakDWGPDF-
T-FW-B18 TPO Coated Metal Right Angle Base Tie-InDWGPDF-
T-FW-B19 Spliced TPO Coated Metal Right Angle Base Tie-InDWGPDF-

INTERMEDIATE TERMINATION DETAILSCADPDF BIM
T-FW-I1 TPO Intermediate Membrane Attachment with Fastener & PlateDWGPDF-
T-FW-I2 TPO Cover Strip Wall Flashing Attachment with Fastener & PlateDWGPDF-
T-FW-I3 TPO Intermediate Attachment with Termination BarDWGPDF-
T-FW-I4 Termination Bar Attachment With Welded TPO Cover StripDWGPDF-
T-FW-I5 Continuous Flashing Attachment- Termination BarDWGPDF-
T-FW-I6 Split Flashing Attachment – Termination BarDWGPDFRVT
T-FW-I7 TPO Intermediate Termination with Counterflashing & Cut-In RegletDWGPDFRVT
T-FW-I8 TPO Intermediate Termination with Surface Mounted CounterflashingDWGPDFRVT
T-FW-I9 TPO Intermediate Termination with Through-Wall CounterflashingDWGPDF-
T-FW-I10 TPO Intermediate Termination with Termination BarDWGPDF-
T-FW-I11 TPO Intermediate Termination Below Wall CladdingDWGPDFRVT
T-FW-I12 TPO Intermediate Membrane Attachment w/Termination BarDWGPDF-
T-FW-I13 TPO Intermediate Termination (Loose Hung Flashing)DWGPDF-

TOP OF WALL DETAILSCADPDFBIM
T-FW- T1 Fabricated Metal Coping Over Adhered TPODWGPDFRVT
T-FW- T2 Presto Lock Coping System Over TPODWGPDF-
T-FW- T3 Presto-Tite Fascia System On Sloped ParapetDWGPDF-
T-FW- T4 Perma-Tite Continuous Cleat Coping System Over TPO               DWGPDF-
T-FW- T5 Top of Wall Termination with Stone CopingDWGPDF-

TPO MEMBRANE SEAMING DETAILSCADPDFBIM
T-MS-01 Cut Edge SealantDWGPDF-
T-MS-02 In-Lap Fastening Method-Steel DeckDWGPDF-
T-MS-03 In-Lap Fastening Method-Plywood DeckDWGPDF-
T-MS-04 In-Lap Fastening Method-Concrete DeckDWGPDF-
T-MS-05 In-Lap Fastening Method-Wood Plank DeckDWGPDF-
T-MS-06 Continuous Strip Fastening MethodDWGPDF-
T-MS-07 Membrane Side LapDWGPDF-
T-MS-08 TPO Fleece Backed Adhesive Applied Membrane Butted End LapDWGPDF-
T-MS-09 Slope Transition-ValleyDWGPDF-
T-MS-10 Slope Transition-RidgeDWGPDF-
T-MS-11 TPO Self Adhered Membrane Butted End LapDWGPDF-
T-MS-12 TPO T-Joint PatchDWGPDF-
T-MS-13 Headlap Over Field Seam with T-Joint PatchDWGPDF-

TPO FLASHING CURB & CORNER DETAILSCADPDFBIM
T-FC-01 Prefabricated Metal Curb Base FlashingDWGPDFRVT
T-FC-02 Roof HatchDWGPDF-
T-FC-03 Outside CornerDWGPDF-
T-FC-04 Inside CornerDWGPDF-
T-FC-05 TPO Wood Curb Base FlashingDWGPDF-
T-FC-06 TPO Flashing Wall with Term Bar and Corner CopingDWGPDF - 
T-FC-07 Membrane Attachment Outside CornerDWGPDF-
T-FC-08 Membrane Attachment Inside CornerDWGPDF-
T-FC-09 Outside Corner with TPO Coated Metal with BreakDWGPDF-
T-FC-10 Outside Corner with TPO Coated MetalDWGPDF-
T-FC-11 Inside Corner with TPO Coated Metal with BreakDWGPDF-
T-FC-12 Inside Corner with TPO Coated MetalDWGPDF-
T-FC-13 RTU Curb Flashing with Metal Counter FlashingDWGPDF-
T-FC-14 RTU Curb Flashing with Substrate Mounted FlangeDWGPDF-

TPO PROTECTION DETAILSCADPDFBIM
T-PT-01 Support-LightDWGPDF-
T-PT-02 Support-MediumDWGPDF-
T-PT-03 Support-HeavyDWGPDF-
T-PT-04 Walkway-Concrete PaverDWGPDF-
T-PT-05 TPO Walkpads Over Adhered TPO MembraneDWGPDFRVT
T-PT-06 TPO Walkpad Fleece Backed System Fully AdheredDWGPDF-
T-PT-07 TPO Walkpad Over Mechanically Fastened TPO MembraneDWGPDF-
T-PT-08 Lightning Rod-Wall MountDWGPDF-
T-PT-09 Lightning Rod-Roof MountDWGPDF-
T-PT-10 Grease TrapDWGPDF-
T-PT-11 JM Single Ply Safety Strip Over TPO MembraneDWGPDF-
T-PT-12 JM ENRGY Anchor - TPODWGPDF-
T-PT-13 Hurricane Peel Stop Anchor BarDWGPDF-

TPO COVER TAPE DETAILSCADPDFBIM
T-FE-C1 Metal Drip Edge with TPO Cover TapeDWGPDFRVT
T-FE-C2 Gravel Stop with TPO Cover TapeDWGPDFRVT
T-FE-C3 Gutter & Metal Edge with TPO Cover TapeDWGPDFRVT

 
TPO Heat Weldable Cover Tape DetailsCADPDFBIM
T-FE-C4 Metal Drip Edge with JM TPO Heat Weldable Cover TapeDWGPDF-
T-FE-C4I Metal Drip Edge with JM TPO Heat Weldable Cover Tape
DWGPDF-

TPO COATED METAL DETAILSCADPDFBIM
T-FE-CM1 Drip Edge-TPO Coated MetalDWGPDF-
T-FE-CM2 Drip Edge-TPO Coated Metal Adhered Membrane OnlyDWGPDF-
T-FE-CM3 Gravel Stop-TPO Coated MetalDWGPDF-
T-FE-CM4 Gravel Stop-TPO Coated Metal Adhered Membrane OnlyDWGPDF-
T-FE-CM5 Gutter & TPO Coated Metal EdgeDWGPDFRVT
T-FE-CM6 Butt Joint At Edge-TPO Coated MetalDWGPDF-

PRE-MANUFACTURED (METAL) DETAILSCADPDFBIM
T-FE-P1 JM Presto Tite Drip EdgeDWGPDF-
T-FE-P2 JM Presto-Tite Fascia System For Single Ply SystemsDWGPDF-
T-FE-P3 JM Presto Tite Edge OneDWGPDF-
T-FE-P4 JM Perma-Tite System 200 FasciaDWGPDF-
T-FE-P5 JM Metal Drip Edge With TPO Cover TapeDWGPDF-
T-FE-P6 JM Gravel Stop With TPO Cover TapeDWGPDF-
T-FE-P7 JMTPO Presto Weld Drip EdgeDWGPDF-
T-FE-P8 Extended JM Presto Tile FasciaDWGPDF-

TPO DRAINS & VENTS DETAILSCADPDFBIM
T-DV-01 Vent PipeDWGPDFRVT
T-DV-02 Vent Pipe-HotDWGPDFRVT
T-DV-03 Through-wall ScupperDWGPDFRVT
T-DV-03I Through-wall  ScupperDWGPDFRVT
T-DV-04 Primary Scupper With Tapered Insulation SumpDWGPDFRVT
T-DV-05 Low-Wall Primary Scupper FlashingDWGPDFRVT
T-DV-06 Overflow ScupperDWGPDFRVT
T-DV-07 Primary Drain Sump-Low Slope-Up To 3:12 SlopeDWGPDFRVT
T-DV-08 Primary Drain Sump-Steep Slope-Greater Than 3:12 SlopeDWGPDF-
T-DV-09 Primary Drain Sump-Fleece Backed MembraneDWGPDF-
T-DV-09I TPO Fleece Backed Adhesive Applied Primary Drain In SumpDWGPDF-
T-DV-10 JM Heavy Duty TPO Retro DrainDWGPDFRVT
T-DV-11 Primary Drain Sump-Mechanically Fastened MembraneDWGPDFRVT
T-DV-12 Primary and Overflow Drain SumpDWGPDF - 
T-DV-13 JM TPO Hercules RetrodrainDWGPDF - 
T-DV-14 Roof DrainDWGPDF-
T-DV-15 Overflow Roof Drain with Water DamDWGPDF-
T-DV-16 Primary Roof Drain Insert 6:12 SlopeDWGPDF-
T-DV-17 Primary and Overflow Roof DrainDWGPDF-

TPO FLASHING PENETRATION DETAILSCADPDFBIM
T-FP-01 TPO Pipe BootDWGPDFRVT
T-FP-02 JM TPO 2 Piece Penetration PocketDWGPDFRVT
T-FP-03  TPO-Coated Metal Penetration PocketDWGPDF-
T-FP-04  TPO Split Pipe Boot-RoundDWGPDFRVT
T-FP-05  TPO Split Pipe Boot-SquareDWGPDFRVT
T-FP-06  TPO Split Pipe Boot-Square-ClampedDWGPDF-
T-FP-07  Field Fabricated Pipe PenetrationDWGPDFRVT
T-FP-08 TPO Peel and Stick Pipe BootDWGPDF - 
T-FP-09 Multi-Pipe with TPO Coated Metal Penetration PocketDWGPDF-
T-FP-10 Multi-Pipe with Fabricated Metal Penetration PocketDWGPDF-

TPO TIE-IN FLASHING DETAILSCADPDFBIM
T-TI-01  Transition For Staged Roofing With TPO Coated Metal                                DWGPDF-
T-TI-02  Transition To Shingle Roof With TPO Coated MetalDWGPDF-
T-TI-03  Curb Tie-In To Roof By OthersDWGPDFRVT

TPO EXPANSION JOINT DETAILSCADPDFBIM
T-EJ-01 Expansion Joint-Roof To WallDWGPDFRVT
T-EJ-02 Expansion Joint-Roof To RoofDWGPDFRVT
T-EJ-03 Expand-O-Flash Roof To Roof Expansion Joint Cover-Style EJDWGPDF-
T-EJ-04 Expand-O-Flash Roof To Wall-Style EJDWGPDF-
T-EJ-05 Expand-O-Flash Curb To Curb Expansion Joint Cover-Style CFDWGPDF-
T-EJ-06 Expand-O-Flash Curb To Wall Expansion Joint Cover-Style CF/EJDWGPDF-
T-EJ-07 Expand-O-Flash Curb to Wall (Style TPO EJ-WC)DWGPDF - 
T-EJ-08 Expand-O-Flash Curb to Curb (Style PVC EJ-WC)DWGPDF - 
T-EJ-09 Expand-O-Flash Curb to Wall Expansion Joint Cover-Style CF/EJDWGPDF-
T-EJ-10 Expand-O-Flash Curb Expansion Joint CoverDWGPDF-

TPO with White EPDM Flashing DetailsCADPDFBIM
TWE-DV-02 - TPO Vent Stack (Hot) with JM White EPDMDWGPDF-
TWE-DV-03 - Through-Wall Scupper with JM White EPDMDWGPDF-
TWE-DV-06 - Overflow Scupper with JM White EPDMDWGPDF-
TWE-FC-03 - TPO Outside Corner with JM White EPDMDWGPDF-
TWE-FC-04 - TPO Inside Corner with JM White EPDMDWGPDF-
TWE-FP-04 - TPO Field Fabricated Pipe Wrap with JM White EPDMDWGPDF-
TWE-FW-01 - TPO End Wall Transistion with JM White EPDMDWGPDF-

VARIOUS (MISCELLANEOUS) DETAILSCADPDFBIM
T-FE-V1 Wood Nailer AttachementDWGPDF-
T-FE-V2 Gutter & Termination BarDWGPDF-
T-FE-V3 RhinoPlate-Standing Seam Retro-Fit Purlin AttachmentDWGPDF-
T-FE-V4 RhinoPlate-Standing Seam Retro-Fit Gravel StopDWGPDF-
T-FE-V5 RhinoPlate-Standing Seam Retro-Fit GutterDWGPDF-
T-FE-V6 Gutter and JM Drain BarDWGPDF-

 
SINGLE PLY LIQUID FLASHING CURB AND CORNER DETAILCADDWGBIM
SPL-FC-01 Typical TPO or PVC Door Sill FlashingPDFDWG-

 
SINGLE PLY LIQUID FLASHING DRAINS AND VENTS DETAILSCADPDFBIM
SPL-DV-01 Throughwall Metal Scupper with TPO or PVC MembraneDWGPDF-

 
SINGLE PLY LIQUID FLASHING PENETRATION DETAILSCADPDFBIM
SPL-FP-01 TPO or PVC Roof Multi-Pipe Penetration FlashingDWGPDF-
SPL-FP-03 TPO or PVC Square Tube Penetration FlashingDWGPDF-
SPL-FP-05 TPO or PVC Wide Flange Penetration FlashingDWGPDF-
SPL-FP-07 Wide Flange Flashing Scrim LayoutDWGPDF-
SPL-FP-08 TPO or PVC Angle Iron Penetration FlashingDWGPDF-
SPL-FP-10 Angle Iron Flashing Scrim LayoutDWGPDF-

SINGLE PLY LIQUID FLASHING WALL DETAILCADPDFBIM
SPL-FW-01 Wall Mounted Ladder TPO or PVC Base FlashingDWGPDF-
SPL-FW-03 Deck Mounted Ladder TPO or PVC Base FlashingDWGPDF-
SPL-FW-05 Flashing Wall Optional TerminationsDWGPDF-

SINGLE PLY LIQUID FLASHING EXPANSION JOINTS DETAILS CADPDFBIM
SPL-EJ-01 Expansion Joint TPO or PVC Roof to WallDWGPDF-

SINGLE PLY ONE-PART POURABLE SEALER DETAILSCADPDFBIM
T1P-FP-01 TPO Multi-Pipe Penetration 1-Part Pourable Sealer Liquid FlashingDWGPDF-
T1P-FP-02 TPO Square Tube Penetration 1-Part Pourable Sealer Liquid FlashingDWGPDF-
T1P-FP-03 TPO Wide Flange Penetration 1-Part Pourable Sealer Liquid FlashingDWGPDF-
T1P-FP-04 Wide Flange Flashing Scrim Layout 1-Part Pourable Sealer Liquid FlashingDWGPDF-
T1P-FP-05 TPO Angle Iron Penetration Flashing 1-Part Pourable Sealer Liquid FlashingDWGPDF-
T1P-FP-06 Angle Iron Flashing Scrim Layout 1-Part Pourable Sealer Liquid FlashingDWGPDF-

TPO SELF-ADHERED FLASHING DETAILS CAD   PDF   BIM  
T-FW-B9 TPO Self-Adhered Base Tie-In (Fastener & Plate)DWGPDF-
T-FW-B10 TPO Self-Adhered Base Tie-In (Fastener & Plate) on WallDWGPDF-
T-FW-B11 TPO Self-Adhered Membrane Flashing Base Tie-In (High Internal Pressure)DWGPDF-
T-FW-B12 TPO Self-Adhered Base Tie-In (Fastener & Plate) with TPO Cover StripDWGPDF-
T-FW-M3I Self-Adhered TPO Base & Wall Flashing with Coping ISO ViewDWGPDF-
T-FW-M8I TPO Self-Adhered Continuous Wall FlashingDWGPDF-
T-MS-11 TPO Self-Adhered Membrane Butted End LapDWGPDF-

TPO BITUMINOUS HYBRID DETAILSCADPDFBIM
TH-FW-B1 Base Tie In With Term BarDWGPDF-
TH-FW-B2 Base Tie In (Fastener & Plate) with CantDWGPDF-
TH-FW-B3 Base Tie In (Fastener & Plate) On WallDWGPDF-
TH-FW-B4 Base Tie In With Term BarDWGPDF-
TH-FW-M1 TPO Hybrid Base & Wall Flashing with CopingDWGPDF-
TH-FW-M1I TPO Hybrid Base & Wall Flashing with Coping Isometric ViewDWGPDF-
TH-FW-M2I Highwall Flashing with Metal Backing Strip Isometric ViewDWGPDF-
TH-MS-01 TPO Fleece Backed Membrane Butted End LapDWGPDF-
TH-FC-01 Prefabricated Metal Curb Base Flashing with CantDWGPDF-
TH-FC-02 Prefabricated Metal Curb Base FlashingDWGPDF-
TH-FE-CM1 Drip Edge (TPO Coated Metal)DWGPDF-
TH-FE-CM2 Gravel Stop (TPO Coated Metal)DWGPDF-
TH-FE-CM3 Gutter & TPO Coated Metal EdgeDWGPDF-
TH-FE-P1 JM Presto-TIte Edge One Fascia SystemDWGPDF-
TH-FE-P2 Presto Tite Fascia SystemDWGPDF-
TH-DV-01 Field Fabricated Vent PipeDWGPDF-
TH-DV-02 Drain DetailDWGPDF-
TH-DV-03 Vent PipeDWGPDF-
TH-FP-01 Pipe BootDWGPDF-

VAPOR BARRIER SA DETAILSCADPDFBIM
VB-1 JM Vapor Barrier SA - Wall Base DetailDWGPDF-
VB-1 (ALT) JM Vapor Barrier SA - Wall Base Detail - Alt                                                DWGPDF-
VB-2 JM Vapor Barrier SA - Pipe Penetration DetailDWGPDF-
VB-3 JM Vapor Barrier SA - Drain DetailDWGPDF-
VB-4 JM Vapor Barrier SA - Detail at Field LapsDWGPDF-
VB-5 JM Vapor Barrier SA - Outside Curb DetailDWGPDF-
VB-6 JM Vapor Barrier SA - Inside Curb DetailDWGPDF-

VAPOR BARRIER SAR DETAILS                                                                                            CADPDFBIM
VB-1 JM Vapor Barrier SAR - Wall BaseDWGPDF-
VB-1 (ALT) JM Vapor Barrier SAR - Wall BaseDWGPDF-
VB-2 JM Vapor Barrier SAR - Pipe PenetrationDWGPDF-
VB-3 JM Vapor Barrier SAR - DrainDWGPDF-
VB-4 JM Vapor Barrier SAR - Field LapsDWGPDF-
VB-5 JM Vapor Barrier SAR - Outside CurbDWGPDF-
VB-6 JM Vapor Barrier SAR - Inside CurbDWGPDF-

Maximizing Your Roof's Protection From Hail

When it comes to your roof, hail can cause significant damage. However, incorporating the appropriate cover board into your roofing system can provide you with superior protection. Upgrade your roof to VSH-rated with DexCell FA VSH Glass Mat Roof Board today!

FM VSH Approval Rating Image of Hand with a Hail Ball and Custom Logo

Very Severe Hail is two inches or wider in diameter.

Hail can fall as speeds up to 72 mph

The Very Severe Hail region was recently expanded. Are you in the danger zone? Visit the FM Global natural hazards map here.


TPO Roof Cut Study

Back in 2010, we introduced the inaugural TPO Challenge, and to this day, we continue organizing these events. More than 1,000 contractors, specifiers, consultants, welders, and other roofing experts have participated in blind challenges across the country to compare various top TPO membranes. Among skilled welders, 70% of them opted for JM TPO as their preferred membrane.

Resources

JM ENRGY Anchor

JM TPO

Hear more about what it means to JM on what it takes to make an exceptional  TPO product.

JM TPO is Preferred by Top Contractors

We sat down with a few of our top contractors and learned how much the quality of JM TPO matters to getting the job done right.

JM TPO Rhinobond in Action

Check out how Great Lakes Roofing uses the JM 60 mil TPO Rhinobond Systems with a 20 Year NDL.

The Original Roofing Company Uses JM BUR System to Get Job Done

The Original Roofing Company (TORC) won a new build project in southwest Las Vegas from general contractor Martin-Harris Construction for a 200,000 square foot mixed use office and warehouse structure in an area with industrial. buildings, car dealerships and residential housing.

Project Sugar in Colorado uses ProtectoR HD as a Key Product in New Construction

Against the backdrop of the Rocky Mountains’ Front Range, commercial real estate developer Trammell Crow Company (TCC) transformed 70 acres of farmland into an industrial park. All new infrastructure—roads, electricity, water, sewage—was put into place before a massive 818,300 square foot roofing project was constructed.

JM and Barber and Associates Skillfully Navigate Supply Chain to Complete Job

With today's current economic status, supply chain is a common issue across the country. For this 23 acre job in Florida, Johns Manville and Barber and Associates worked together to defy supply chain issues to meet the project deadline.

New JM TPO 12 Foot Rolls Lead to an Increase in Productivity

The site of a nearly 170,000 square foot former Menards home improvement store was refurbished and reconfigured to house a host of retailers including: movie theaters, an indoor skydiving venue, a Planet Fitness gym and many others. Located near the Chicagoland Territory, the reroofing was completed in September 2018.

Chicago Premium Outlets Project Shines with JM TPO System

The Chicago Premium Outlets 250,000-square-foot expansion includes 30 new or expanded stores, two new restaurants, 2,200 additional parking spaces, public art, outdoor fireplaces and a large pond. According to Mike Reynolds, senior project manager for Olsson Roofing Company, Inc., “Chicago Premium Outlets is more of a pedestrian mall since the expansion.” 

Largest Building in Maryland Roofed by Johns Manville

The former Bethlehem Steel manufacturing site at Tradepoint St. John’s is getting new life in a modern building as a distribution center for a clothing manufacturer. Proximity to rail, land and water makes this location ideal for global companies to expedite both their shipping and receiving operations.

Building Owner Resources

Johns Manville offers one of the most comprehensive portfolios of commercial low-slope roofing solutions. We have a long standing dedication to providing solution-based systems for building owners.

Codes Corner

Here you will find quick links and cheat sheets to Johns Manville roofing systems code approvals and ratings. 

Guarantees and Roof Maintenance

Support services can include: conceptual product information, building science, wind uplift data, national and local code understanding, FM Global® and UL® regulations, fastening patterns and sheet layouts, installation guidelines and standard details.

Recycling Resources

Re-roofing mechanically attached or ballasted insulated single-ply systems now have the potential for recycling versus contributing to a landfill.

SmartBinder Resource Library 

Your resource for all JM documents in one place. 

Submittal Wizard

The Submittal Wizard is a tool to help you pull together the necessary documents for your submittal package.

Explore More

JM ENRGY Anchor

Commercial Roofing News

Blog

Commercial Roofing Blog

Watch On-Demand

Video Library

Roofing Video Library

Expand Your Knowledge

Training

Training Page