Stainless Steel Roll Jacketing

Stainless Steel Roll Jacketing

Product Descriptive Name
Product Short Description
Manufactured from T-304 and T-316 prime grade Stainless Steels. 

Product Details

Stainless Steel Roll Jacketing

JM's Stainless Steel Roll Jacketing is manufactured from T-304 and T-316 prime grade Stainless Steels. These alloys comply with ASTM A-240, and are supplied with a regular dull finish for reduced glare. The yield strength is 30,000-45,000 PSI and the tensile strength is 75,000-110,000 PSI. These alloys are of a special soft-annealed temper, for ease in fabrication. T-304 is normally used in all except the most corrosive areas, where T-316 is recommended. 
The 300 series Stainless Steels have a melt point of approximately 2500°F, providing optimum fire protection. Stainless Steel has a higher emittance value than Aluminum, and has physical properties superior to all other metal used as insulation protective jacketing. T-304 contains 18% chromium and 8% nickel. T-316 contains 16.5% chromium, 10% nickel and 2.2% molybdenum.

Features

Stainless Steel Roll Jacketing

Compliance to Standards -  All bare and polyfilm lined JM Stainless Steel Jacketing complies with the requirements of ASTM C1767 (Stainless Steel Jacketing Material Standard) which includes the strength and chemical
composition requirements for compliance to ASTM A240 (Stainless Steel Alloy Standard).

Recommended Uses: Steel mils, paper mills, chemical plants and refineries

Polyfilm Moisture Barrier -  Polyfilm consists of a 3 mil thickness of a co-extrusion of polyethylene and DuPont's Surlyn* which is heat laminated to the metal jacketing. Due to its superior performance characteristics, it replaces the old standard 1 mil and 3 mil polykraft moisture barriers. 

Also Available without Polyfilm upon request

Documents

Sign up for Industrial Insulation news & events

Resources

Explore our Industrial insulation tools, education and training programs built specifically to aid you in your professional development

Request a Technical Presentation
Johns Manville offers customized presentations to help you stay up to date on the latest market trends and enhance your knowledge of JM products.

The Source: Industrial Insulation Resource Library
The Source is where we house the latest Insulation Intel® on industry trends, insights, and continuing education opportunities. This is a resource built specifically to aid you in your professional development. Explore our webinars, compare specs, and follow our blog all right here at The Source.

SmartBinder Resource Library 
Your resource for all JM documents in one place. 

Where to Buy
Use our insulation locator tool to find JM products near you.

Resource Pages

Calcium Silicate Pipe and Board Insulation Resource Library
Johns Manville's Thermo-1200® calcium silicate has added corrosion inhibitors, become water-resistant, and is now offered in a curved segment configuration for large diameter (30” – 126”) equipment

Cross-Flo Jacketing Resource Library

Water isn’t welcome inside an insulation system, so get it out – and fast – with the help of Johns Manville’s Cross-Flo Jacketing. This new product is perfect for industrial and mechanical insulation systems, helping to expel unwanted water.

Corrosion Under Insulation (CUI) Resource Library
Thermal insulation is an integral part of the industrial complex. However, even the best designed and installed systems sometimes become compromised, resulting in the presence of water at the pipe surface and the potential for Corrosion under Insulation (CUI). Learn more about CUI and how JM provides the solution. 

Insulation Solutions for Cryogenic and LNG Systems
Cryogenic and below-ambient pipe and tank temperatures can drop to -297°F, making a well-designed insulation system critical to ensure safe and efficient operations in an Liquefied Natural Gas (LNG) facility. At Johns Manville, we’re here to assist you with all the details you need to properly design, specify and install your cryogenic and LNG application.

Case Studies

Berne Processing Complex
The first of three plants for the new $150 million BlueRacer Midstream LLC gas processing facility in Lewisville, Ohio called for high-temperature insulation solutions that would meet the project specifications and aggressive timeframe for delivery.

Newark Energy Center

The construction of the Newark Energy Center gas-fired power plant in Newark, New Jersey called for the latest GE gas turbine technology to supply electricity to more than 700,000 homes. 

CUI Protection at a Refinery
The service crew at a Washington state location put Cross-Flo®jacketing to use on a maintenance project, after first testing theproduct themselves. They’re now hopeful it can be used regularly

Resources

Explore our Industrial insulation tools, education and training programs built specifically to aid you in your professional development

Request a Technical Presentation
Johns Manville offers customized presentations to help you stay up to date on the latest market trends and enhance your knowledge of JM products.

The Source: Industrial Insulation Resource Library
The Source is where we house the latest Insulation Intel® on industry trends, insights, and continuing education opportunities. This is a resource built specifically to aid you in your professional development. Explore our webinars, compare specs, and follow our blog all right here at The Source.

SmartBinder Resource Library 
Your resource for all JM documents in one place. 

Where to Buy
Use our insulation locator tool to find JM products near you.

Resource Pages

Calcium Silicate Pipe and Board Insulation Resource Library
Johns Manville's Thermo-1200® calcium silicate has added corrosion inhibitors, become water-resistant, and is now offered in a curved segment configuration for large diameter (30” – 126”) equipment

Cross-Flo Jacketing Resource Library

Water isn’t welcome inside an insulation system, so get it out – and fast – with the help of Johns Manville’s Cross-Flo Jacketing. This new product is perfect for industrial and mechanical insulation systems, helping to expel unwanted water.

Corrosion Under Insulation (CUI) Resource Library
Thermal insulation is an integral part of the industrial complex. However, even the best designed and installed systems sometimes become compromised, resulting in the presence of water at the pipe surface and the potential for Corrosion under Insulation (CUI). Learn more about CUI and how JM provides the solution. 

Insulation Solutions for Cryogenic and LNG Systems
Cryogenic and below-ambient pipe and tank temperatures can drop to -297°F, making a well-designed insulation system critical to ensure safe and efficient operations in an Liquefied Natural Gas (LNG) facility. At Johns Manville, we’re here to assist you with all the details you need to properly design, specify and install your cryogenic and LNG application.

Case Studies

Newark Energy Center
The construction of the Newark Energy Center gas-fired power plant in Newark, New Jersey called for the latest GE gas turbine technology to supply electricity to more than 700,000 homes. 

Explore More

Industrial Insulation Intel

Blog

Watch On-Demand

Webinars

How to video series

Insulation Minute